Home » products » Load Cells » Shear beam » PTS
Load Cells
Shear beam
Rated load (R.L.): | 500, 1000, 2000, 5000 Kg |
Combined error: | ±0.02% of R.O. |
Repeatability: | ±0.01 % of R.O. |
Creep (30 minutes): | ±0.02% of R.O. |
Safe overload: | 150% of R.L. |
Ultimate overload: | 300% of R.L. |
Recommended input: | 5÷15 Vcc/ca |
Input resistance: | 350 ± 3.5 Ohms |
Output resistance: | 350 ± 3.5 Ohms |
Insulation resistance: | GREATER/EQUAL 5000 M Ohms 50 VDC between the branches of the bridge and the body cell |
Rated output (R.O.): | 3 ± 0.008 mV/V |
Zero balance: | 1% R.O. |
Temperature range: | -35 ÷ +65°C |
Compensated temperature range: | -10 ÷ +40°C |
Temp. effect (-10° to +50°C) on zero balance: | 0.018% SN/10°C |
Temp. effect (-10°C to +50°C) on output: | 0.014% on output/10°C |
Degree of protection: | IP67 |
Material: | Stainless steel |
Electrical connection: | 4 conductors shielded cable; length 6 m |
Precision class: | 3000 n. OIML |