Home » products » Load Cells » High Temperature » CVS HT
Load Cells
High Temperature
Rated load (R.L.): | 500, 1000, 2000, 5000, 10000, 20000, 30000, 60000, 100000 kg |
Combined error: | ± 0.08 % of R.O. |
Repeatability: | ± 0.02 % of R.O. |
Creep (20 minutes): | ± 0.02 % of R.O. |
Safe overload: | 150% of R.L. |
Maximum overload: | > 300% of R.L. |
Recommended input: | 2÷15 Vcc/ca |
Input resistance: | 700 ± 20 Ohms |
Output resistance: | 700 ± 5 Ohms |
Insulation resistance: | >5000 MOhms |
Nominal sensitivity: | 2.0 mV/V ± 0.1% |
Zero balance: | < ±1.5% of R.O. |
Temperature range: | -20 ÷ +120 °C (other Temperature Range on request) |
Compensated temperature range: | -10 ÷ +90 °C (other Temperature Range on request) |
Temp. effect on zero balance: | < ±0.005% of R.O./°C |
Temp. effect on output: | < ±0.005% of applied load/°C |
Max load deflection: | 0.35mm |
Degree of protection: | IP67 |
Material: | Stainless steel |
Electrical connections: | M8-PG7 cable gland, 4-conductor shielded cable L = 5m |