Home » products » Load Cells » Off Center » 1260
Load Cells
Off Center
Rated capacity—R.C. (Emax): | 50, 75, 100, 150, 250, 300, 500, 635kg |
Rated output (R.O.): | 2.0 mV/V |
Zero balance: | 0.2 ±mV/V |
Creep (30 min.): | 0.0170 ±% of applied load |
Total error: | 0.0200 ±% of rated output |
Temperature effect on zero: | 0.0023 ±% of rated output/°C |
Temperature effect on output | 0.0010 ±% of applied load/°C |
Temperature range, compensated: | –10 to +40 °C |
Temperature range, safe: | –20 to +70 °C |
Maximum safe central overload: | 150 % of R.C. |
Ultimate central overload: | 300 % of R.C. |
Excitation, recommended: | 10 VDC or VAC RMS |
Excitation, maximum: | 15 VDC or VAC RMS |
Input impedance: | 415±15 Ohms |
Output impedance: | 350±3 Ohms |
Insulation resistance: | >2000 MOhms |
Cable length: | 3mt |
Cable type: | 6-wire, braided, polyurethane, dual floating screen |
Environmental protection: | IP66 |
Platform size (max): | 600 x 600 mm |