Home » products » Weighing Inst. » Weight Transmitters » DAT 400/DEVICENET


DAT 400/DEVICENET

31/2015

Weighing Inst. Weight Transmitters

Weighing Inst.

Weight Transmitters





TECHNICAL CHARACTERISTICS DAT 400/DEVICENET

Trasducer input voltage: 5 V (max 6 load cells 350 Ohm)
Measuring range: -0.5 ÷ +3.5 mV/V (-3.9 ÷ +3.9 mV/V optional)
Input sensitivity: 0.02 microV/division
Linearity: < 0.01% FS
Gain, drift: < 0.001% FS/ °C
Display: 6 digit, red LED (7 segments), h 14 mm
A/D Converter: 24 bit
Resolution: > 16.000.000 counts
Visible resolution: 60.000 divisions displayable on net weight
Divisions value (adjustable): x1, x2, x5
Decimal: 0.0 ; 0.00 ; 0.000
Filter: 0.1÷25 Hz adjustable
Keyboard: 4 tactile feedback buttons
Tool voltage: 24 Vcc ±15% - power 5 W
Temperature range: -10 ÷ +50 °C
Storage Temperature: -20/+70°C
Logic output: 2 Solid-state relays, (maximum load 24 Vdc / 100 mA each)
Logic input: 2 optoisolated 24 Vcc PNP (External voltage)
Serial door: USB, RS232C with ASCII or Modbus RTU protocols
Transmission distance: 15m (RS232C)
Peak Hold function: only for dynamics measures
Baud rate: 2400, 9600, 19200, 38400, 115200 adjustable (for RS232)
Regulatory compliance: EN61326-1, EN55011 and EN55014 for EMC; EN61010-1 for electrical security
Electrical connection: Screw terminals 5 mm
Dimensions and weight: 106 x 90 x 58 mm (L x H x P); 250 g
FieldBUS protocol: DEVICENET

Accessories are not to be considered included in the price of each product.
All the above is purely illustrative and not to be understood demanding towardsPrecise Instrument Corporation