Home » products » Load Cells » BLH Nobel » KIS-8
Load Cells
BLH Nobel
Applications:
Rated load (R.L.): | 1, 2, 5, 10, 20, 50, 100, 200 kN |
Combined error: | ±0.075% of R.O. |
Repeatability: | ±0.02% of R.O. |
Safe overload: | 50% of R.L.* |
Ultimate overload: | 100% of R.L.* |
Ultimate sideload: | 100% of R.L.* |
Recommended input: | 5 Vdc or Vac |
Input voltage maximum: | 18 Vdc or Vac |
Input resistance: | 350 ± 5 Ohms |
Output resistance: | 350 ± 0.5 Ohms |
Rated output (R.O.): | 2.040 mV/V ±0.25% |
Zero balance: | ±2% of R.O. |
Tolerance of shunt calibration values: | ±0.25% of value** |
Creep (30 minutes): | ±0.03% of R.L. |
Temperature range: | - 40 ÷ + 80 (+ 100) °C *** |
Temp. effect (-10°C to +50°C) (14 to 120°F) On output: | ±0.003% of output/°C |
Temp. effect (-10°C to +50°C) (14 to 120°F) On Zero balance: | ±0.003% of R.O./°C |
Insulation resistance at 200V DC: | > 4 G Ohms |
Material (load cell): | Stainless steel |
Electrical connection: | 5 m shielded four conductor cable 1, 2, 5, 10, 20 kN |
10 m shielded cable with four conductors 50, 100, 200 kN | |
Degree of protection: | IP67 |
ATEX certified versions available for use in hazardous areas are available II 1GD | |
* With reference to the loading point recommended | |
** See the calibration chart of the load cell | |
*** On demand -40° ÷ +100°C |