Home » products » Load Cells » BLH Nobel » KIS-11


KIS-11

32/2014

Load Cells BLH Nobel

Load Cells

BLH Nobel




Applications:

  • Batch/blend/mix systems
  • Reactor vessels 
  • Quality-critical process weighing 
  • Precision force measurement

TECHNICAL CHARACTERISTICS KIS-11

Rated load (R.L.): 50 kN
Combined error: ±0.02% of R.O.
Repeatability: 0.01% of R.O.
Safe overload: 100*% of R.L.
Ultimate overload: 200*% of R.L.
Safe sideload: 100*% of R.L.
Ultimate sideload: 200*% of R.L.
Recommended input: 5 V DC or AC
Input voltage maximum: 18 V DC or AC
Input resistance: 350 ± 3 Ohms
Output resistance: 350 ± 0.5 Ohms
Rated output (R.O.): 1.020 mV/V ±0.1%
Zero balance: ±1% of R.O.
Creep (30 minutes): ±0.04% of R.L.
Temperature range: -40 ÷ +80 (+100)*** °C
Temp. effect (-10°C to +50°C) (14 to 120°F) on output: ±0.0010% on output/°C
Temp. effect (-10°C to +50°C) (14 to 120°F) On Zero balance: ±0.0014% of R.O./°C
Insulation resistance at 200 V DC: > 4 G Ohms
Material (load cell): Stainless steel
Material (accessories): Yellow chromate steel****
Electrical connection: 10m shielded four conductor cable
Degree of protection: IP67
ATEX certified versions for use in explosive atmospheres are available: II 1GD
* Referring to recommended loading case
*** -40° ÷ +100°C on demand
**** Stainless steel on demand
Approved in accordance with international recommendations OIML R 60 1991 edition, C3.

Accessories are not to be considered included in the price of each product.
All the above is purely illustrative and not to be understood demanding towardsPrecise Instrument Corporation