Home » products » Load Cells » BLH Nobel » KIM-1


KIM-1

42/2012

Load Cells BLH Nobel

Load Cells

BLH Nobel




Applications:

  • Silos/bin/hopper inventory weighing systems
  • Mixing tanks, mixing and dissolving reactors
  • Force measurement systems
  • Conveyors 

TECHNICAL CHARACTERISTICS KIM-1

Rated load (R.L.): 200 kN
Combined error: ±0.1% of R.O.
Repeatability: 0.02% of R.O.
Safe overload: 50% of R.L.
Ultimate overload: 100% of R.L.
Sideload Ultimate: 100 % of R.L.
Recommended input: 5 V DC or AC
Input voltage maximum: 18 V DC or AC
Input resistance: 350 ± 5 Ohms
Output resistance: 350 ± 0.5 Ohms
Rated output (R.O.): 2.040 mV/V ±0.25%
Zero balance: ±2% of R.O.
Tolerance of shunt calibration values: ±0.25%
Creep (30 minutes): ±0.03% of R.L.
Temperature range: -40 ÷ +100 °C
Temp. effect (-10° to +50°C) on output: ±0.003% on output/°C
Temp. effect (-10°C to +50°C) (14 to 120°F) On Zero balance: ±0.003% of R.O./°C
Deflection at R.L.: 0.1 - 0.3 mm
Insulation resistance at 200V DC: > 4 G Ohms
Electrical connection: 10m four conductor cable
Degree of protection: IP67

Accessories are not to be considered included in the price of each product.
All the above is purely illustrative and not to be understood demanding towardsPrecise Instrument Corporation