Load Cells
Universal
Severity: Warning
Message: Undefined property: stdClass::$SchedaTecnica
Filename: views/dettaglio_prodotto.php
Line Number: 59
| Capacity: | 50, 100, 250, 500, 1000, 2500 kg |
| Accuracy class: | 3000 OIML |
| Safe overload: | 300% FS |
| Total error: | < ± 0,017% FS |
| Repeatability error: | < ± 0,015% FS |
| Temperature effect on zero: | < ± 0,01% FS/5°K |
| Temperature effect on sensitivity: | < ± 0,006% FS/5°K |
| Creep: | < ± 0,016% FS |
| Compensated temperature: | -10/+40 °C |
| Temperature limits: | -30/+70 °C |
| Nominal sensitivity (Sn): | 2 ± 0,1% mV/V |
| Nominal input voltage: | 10V |
| Maximum input voltage: | 15V |
| Input impedance: | 400 ±20 Ohms |
| Output impedance: | 350 ±3 Ohms |
| Insulation resistance: | > 5000 M Ohms |
| Maximum deflection (at Ln): | 0.3-0.5 mm |