Home » products » Load Cells » Double-Ended Shear Beam » 460


460

39/2015

Load Cells Double-Ended Shear Beam

Load Cells

Double-Ended Shear Beam





TECHNICAL CHARACTERISTICS 460

Rated load (R.L.): 3 ton (NO OIML), 5, 10, 20, 30, 50, 75, 100 ton
Combined error: < ±0.017% of R.O.
Repeatability: < ±0.015% of R.O.
Creep (20 minutes): < ±0.016% of R.L.
Safe overload: 150% of R.L.
Ultimate overload: 200% of R.L.
Recommended input: 5÷15 Vdc/Vac
Input resistance: 800 ± 20 Ohm
Output resistance: 700 ± 3 Ohm
Insulation resistance: > 5000 M Ohm
Rated output (R.O.): 2 ± 0.1% mV/V
Zero balance: < ±2% of R.O.
Temperature range: -30 ÷ +70 °C
Compensated temperature range: -10 ÷ +40 °C
Temperature effect on zero balance: < ±0.010% of R.O./5°K
Temperature effect on output: < ±0.006% on output/5°K
Max load deflection: 0.6÷1 mm
Precision class: 3000 n. OIML
Degree of protection: IP68
Electrical connection: 6 conductors shielded cable; length 12 m

Accessories are not to be considered included in the price of each product.
All the above is purely illustrative and not to be understood demanding towardsPrecise Instrument Corporation