Home » products » Load Cells » Universal » CVF


CVF

40/2014

Load Cells Universal

Load Cells

Universal





TECHNICAL CHARACTERISTICS CVF

Rated load (R.L.): 0.5÷5000 kN
Combined error: ±0.05% of R.O.
Repeatability: ±0.02% of R.O.
Creep (20 minutes): ±0.02% of R.L.
Safe overload: 150% of R.L.
Ultimate overload: > 300% of R.L.
Recommended input: 2÷15 Vdc/Vac
Input resistance: 700 ±20 Ohm (350 Ohm carrying capacity 1000÷5000 kN)
Output resistance: 700 ±5 Ohm (350 Ohm carrying capacity 1000÷5000 kN)
Insulation resistance > 5000 M Ohm
Rated output (R.O.): 2.0 mV/V ±0.1 %
Zero balance: < ±1.5% of R.O.
Temperature range: -20 ÷ +70 °C
Compensated temperature range: -10 ÷ +50 °C
Temp. effect (-10° to +50°C) on zero balance: < ±0.005% of R.O./°C
Temp. effect (-10°C to +50°C) on output: < ±0.005% on output/°C
Max load deflection: 0.2 mm
Degree of protection: IP65
Material: Inox steel
Electrical connection: 6 conductors

Accessories are not to be considered included in the price of each product.
All the above is purely illustrative and not to be understood demanding towardsPrecise Instrument Corporation