Home » products » Load Cells » BLH Nobel » KIMD-M


KIMD-M

37/2014

Load Cells BLH Nobel

Load Cells

BLH Nobel





TECHNICAL CHARACTERISTICS KIMD-M

Rated load (R.L.): 500, 1000, 1500, 2000 kN
Combined error (terminal): ±0.1% of R.O.
Repeatability: 0.02% of R.O.
Safe overload: 100% of R.L.*
Ultimate overload: 200% of R.L.*
Recommended input: 10 Vdc/ac
Input voltage maximum: 18 Vdc/ac
Input resistance: 350 ± 5 Ohm
Output resistance: 350 ± 0.5 Ohm
Rated output (R.O.): 1.0 mV/V ±0.25%
Tolerance of shunt calibration values: ±0.25% of value**
Creep (30 minutes): ±0.03% of R.L.
Temperature range: -40 / +80 (+100)°C***
Temp. effect (-10 to +50°C) on output: ±0.005% of output/°C
Temp. effect (-10° to +50°C) on zero balance: ±0.005% of R.O./°C
Insulation resistance at 200V DC: > 4 G Ohm
Material: Yellow chromate steel
Electrical connection: 10m shielded four conductor cable
Degree of protection: IP67
* With reference to the loading point recommended
** See the calibration chart of the load cell
*** -40° ÷ +100°C on demand
ATEX certified versions for use in explosive atmospheres are available II 1GD EEx ia IIC T4 Tamb = 60°C

Accessories are not to be considered included in the price of each product.
All the above is purely illustrative and not to be understood demanding towardsPrecise Instrument Corporation