Home » products » Load Cells » Double-Ended Shear Beam » MASTERMOUNT
Load Cells
Double-Ended Shear Beam
Rated load (R.L.): | 2, 5, 10, 15, 20, 30 t |
Rated Output (R.O.): | 2.0(±0.25%) mV/V |
Recommended input: | 10 V |
Input voltage maximum: | 18 V |
Safe overload: | 150% of R.L. |
Ultimate overload: | 300 % of R.L. |
Safe sideload: | 30% R.L. |
Ultimate sideload: | 100% of R.L. |
Combined Error: | < ±0.03 % R.O. |
Repeatability: | < ±0.015 % R.O. |
Input resistance: | 785 ± 20 Ohm |
Output resistance: | 700 ± 5 Ohm |
Temperature range: | -50 to +80 °C |
Compensated temperature range: | -10 to +40 °C |
Temperature effect on zero balance: | < ±0.002% SN/°C |
Temperature effect on output: | < ±0.0012% of output/°C |
Electrical connection: | 4 conductors, shielded polyurethane cable; L= 20m |
Insulation resistance: | > 500 M Ohm @ 100 Vdc |