Home » products » Load Cells » Off Center » C2G1
Severity: Warning
Message: Undefined property: stdClass::$SchedaTecnica
Filename: views/dettaglio_prodotto.php
Line Number: 40
Load Cells
Off Center
Severity: Warning
Message: Undefined property: stdClass::$SchedaTecnica
Filename: views/dettaglio_prodotto.php
Line Number: 59


| Rated load (RL): | 6 - 10 - 12 - 15 - 20 - 25 - 30 - 35 - 50 - 60 - 100 Kg |
| Non-Linearity: | ±0,015 % of R.O. |
| Repeatability: | ±0,02 % of R.O. |
| Creep (20 minutes): | ±0,02 % of R.L. |
| Safe overload: | 150 % of RL |
| Maximum overload: | 200 % of R.L. |
| Recommended input: | 5 ÷ 12 Vdc/Vac |
| Input resistance: | 420 +30/-20 Ohm |
| Output resistance: | 350 ±5 Ohm |
| Insulation resistance: | > 2000 M Ohm |
| Rated output (R.O.): | 2 ±0.2 mV/V |
| Zero balance: | < ±0.1 mV/V |
| Temperature range: | -10 ÷ +50 °C |
| Compensated temperature range: | -10 ÷ +50 °C |
| Temperature effect on zero balance: | ±0.004 % of R.O./°C |
| Temperature effect on output: | ±0.0012 % of output/°C |
| Max load deflection: | 0.17 ÷ 0.62 mm |
| Precision class: | 3000 n. OIML - 6000 n. OIML |
| Degree of protection: | IP64 |
| Material: | Alluminum alloy |
| Electrical connection: | 4 conductors shielded cable; length 2 m |