Home » products » Weighing Inst. » Weight Transmitters » DAT 400 PBL


DAT 400 PBL

31/2015

Weighing Inst. Weight Transmitters

Weighing Inst.

Weight Transmitters





TECHNICAL CHARACTERISTICS DAT 400 PBL

Trasducer input voltage: 5 V (max 6 load cells 350 Ohm)
Measuring range: -0.5÷+3..5 mV/V (-3.9÷+3.9 mV/V optional)
Input sensitivity: 0.02 µV/ per count
Linearity: <0.01% of full scale
Gain drift: <0.001% full scale/ °C
Display: 6 digit, red LED (7 segments), h 14 mm
A/D Converter: 24 bit
Resolution: > 16.000.000 counts
Visible resolution: 60.000 divisions displayable on net weight
Set decimal: 0,0; 0,00; 0,000
Filter: 0.1 ÷ 25 Hz adjustable
Keyboard: 4 tactile feedback buttons
Tool voltage: 230 Vac 50 Hz - power 5 W
Temperature range: -10 ÷ +50 °C
Storage temperature: -20 ÷ +70°C
Logic output: 2 Solid-state relays, (maximum load 24 Vdc / 100 mA each)
Logic input: 2 optoisolated 24 V c.c. PNP (External voltage)
Serial door: USB, RS232C or RS422/RS485 with ASCII or Modbus RTU protocols
Transmission distance: 15m (RS232C), 1000m (RS422 e RS485)
FIELDBUS protocol: PROFIBUS, DEVICENET, ETHERNET, PROFINET (opzional)
Others fieldbus comunication: CANopen, Modbus-Plus and other, Precise Gateway 3000 (opzional)
Peak Hold function: only for dynamics measures
Baud rate: 2400, 9600, 19200, 38400, 115200 adjustable
Analog optional output: optoisolated 16 Bit Tension: 0÷5/10V (R min10 Ohm) Current: 0/4÷20mA (R max 300 Ohm)
Regulatory compliance: EN50081-1, EN50082-2 for EMC; EN61010-1 for Electrical security
Electrical connection: Terminal screw pass 5 mm and 4 cable glands PG9
Dimensions and weight: 298x260x140 (LxHxD)
Distance between the fixing holes (4): 200x161 (LxH)

Accessories are not to be considered included in the price of each product.
All the above is purely illustrative and not to be understood demanding towardsPrecise Instrument Corporation