Home » products » Load Cells » Compression » 2000


2000

20/2012

Load Cells Compression

Load Cells

Compression





TECHNICAL CHARACTERISTICS 2000

Rated load (R.L.): 2500, 5000, 10000, 20000, 30000 kg
Combined Error: ±0.05% of R.O.
Repeatability: ±0.02% of R.O.
Creep (20 minutes): ±0.03% of R.L.
Safe overload: 150% of R.L.
Ultimate overload: > 300% of R.L.
Recommended input: 5÷15 Vdc/Vac
Input resistance: 700 ± 20 Ohm
Output resistance: 700 ± 5 Ohm
Insulation resistance: > 5000 M Ohm
Rated output (R.O.): 2 mV/V
Zero balance: ±1% of R.O.
Temperature range: -20 ÷ +70 °C
Compensated Temperature Range: -10 ÷ +50 °C
Temp. effect (-10°C to +50°C) on output: ±0.005 % of output/°C
Temp. effect (-10° to +50°C) on zero balance: ±0.005% of R.O./°C
Max load deflection: < 0.3mm
Degree of protection: IP67
Material: Stainless steel
Electrical connection: 6 conductors shielded cable; length 4 m

Accessories are not to be considered included in the price of each product.
All the above is purely illustrative and not to be understood demanding towardsPrecise Instrument Corporation