Resolution: | 8300000 counts |
Conversion Speed: | 0.5 to 300Hz, accuracy 0.015% |
Full Scale Range: | ± 3.3mV/V |
Linearity: | <0.005% of used range |
Excitation Voltage: | 8.8Vdc to 5.5Vdc with 1 to 8 of 350 ohm transducers, isolated 500V |
Filter: | 0.05 to 75Hz, type FIR, selectable bandwidth |
Offset, drift: | <0.04 microV/°C |
Gain drift: | <0.0015% of full scale |
Temperature range: | - 10°C to + 50°C |
Storage Temperature: | - 25°C to + 85°C |
Display: | 2 x 16 character LCD display with backlight |
Voltage: | 24 VDC ± 20% |
Power Consumption: | 7W |
Isolation: | Digital inputs common with power supply. Other parts - 500V |
Analog output Type: | Isolated 16-bit bipolar D/A converter |
Analog output Accuracy: | 0.04% |
Analog output Non-Linearity: | <0.01% of full scale |
Aalog output Gain Drift: | <0.003% of full scale/°C |
Analog output voltage: | 0-10 or ± 10 VDC |
Analog output Load Data: | min 500 Ohms, max 500 Ohms |
Analog output offset drift: | <0.35mV/°C |
Analog output current: | 0-20mA, ± 20mA, 4-20mA or - 12-20mA |
Analog output offset drift: | <0.7 microA/°C |
Digital inputs: | 2 pcs (option) |
Digital inputs Type and Load: | 24 Vdc, 6mA |
Load: | Max 1A, 30 V AC or DC |
Interface: | RS-485 (two-wires or four-wires), isolated 500V |
Protocol: | MODBUS RTU or ASCII |
Baud Rate: | Up to 115.2 kbaud |
Function: | For control communication (MODBUS RTU) or external display (ASCII) |
Connector Type: | Plug-in screw terminals |