Trasducer input voltage: | 5 V (max 8 celle da 350 Ohms) |
Measuring range: | -3.9 ÷ +3.9 mV/V |
Input sensitivity: | 0.02 µV/ per count |
Linearity: | <0.01% of full scale |
Gain drift: | <0.0003% full scale/ °C |
A/D Converter: | 24 bit |
Visible resolution: | 600.000 divisions displayed on net weight |
Divisions value (adjustable): | x1, x2, x5 |
Set decimal: | 0.0 ; 0.00 ; 0.000; 0.0000 |
Filter: | 0.2 ÷ 50 Hz. 100 Hz during dosage |
Tool voltage: | 230 Vac ±10% - 50/60 Hz absorbed power 7 VA (115 Vac on demand) |
Temperature range: | -10 ÷ +40°C |
Storage temperature: | -20 ÷ +50°C |
Logic input: | 6 relays (NA) MAX 115 Vac /30 Vdc 0.5 A cad. |
Logic input: | 8 optoisolated 12 / 24 Vcc PNP |
Serial door: | COM1: RS232 half duplex max 15m COM2: RS422/RS485 half duplex max 1000m |
FIELDBUS protocol: | ASCII, Modbus RTU, baud rate 1200 ÷ 115K adjustable |
Regulatory compliance: | EN61326, and EN61010-1 |
ATEX II 3 GD EEx nR IIC IP65 T6: | EN 13463-1: 2003; EN 60529: 1991 + A1: 2000 IEC 60079-0: 2004; IEC 60079-15: 2005 |
Optional dosage software: | up to 12 components with external module with 8 relays aggregation of component values and recipe. Management and inventory control. Max 50 programmable recipes |
Analog optional output: | Optically isolated 16-Bit Voltage: 0 to 5 or 0 to 10V (R> 10 Ohms); Current: 0 to 20 or 4 ÷ 20mA (R <300 Ohms); Linearity 0.03% of full scale; Temperature drift 0.001% of full scale /°C |
Optional fieldbus avaiable: | Profibus DP, DeviceNet and ETHERNET TCP-IP external mounting on DIN guide |